| Die configuration | Sealed die |
| Test mode | MDR |
| Temperature control | Dedicated digital temperature controller |
| Temperature range | Ambient temperature to 200℃ |
| Temperature display resolution | 0.01℃ |
| Temperature control stability | ±0.1℃ |
| Temperature accuracy | ≤±0.3℃ |
| Temperature over-heat control | ≤Set value+0.4℃ |
| Temperature recovery time | ≤45 sec |
| Heat-up time | 25 to 190℃ within 6 min |
| Maximum torque | 225 dN-m |
| Torque display resolution | 0.001 unit |
| Torque unit | dN-m, kgf-cm, lbf-in |
| Oscillation amplitude | ±0.5°, ±1.0°, ±2.0°, or ±3.0° (select one) |
| Oscillation frequency | 1.67Hz±0.01Hz |
| Die gap after closing | Adjustable |
| Controller | U70 control system |
| Testing software | Evolution (optional: supports multi-connectivity for up to 4 machines; extra charge) |
| Communication interface | RJ45 |
| Motor | Brushless DC motor |
| Compressed air | 3.5kg/cm² (0.35MPa) (supplied by customer) |
| Dimensions | 55×58×125 (W×D×H) cm |
| Power | 1∮ AC 220V 50/60Hz 800W (or specify) |
| Weight | 167kg |